fcu screwfix. 666. fcu screwfix

 
666fcu screwfix  #4

View all: MK Fused Spurs. Free returns. Sliding Wardrobe Door Tracks Pearwood 2692mm, at Screwfix Direct. Flex Outlet. com. KC DIY, Jun 24, 2021. Ring main feeding FCU with integral RCD, being used to power patio lights and a socket (all outside parts with correct ip rating of course)via 1. I turned the switch on and off a few times, there was a bit of a fizzle noise while the spur tried to come on, So I changed the fuse in the spur, although the old fuse had not blown. 1400W. FREE next day delivery available, free collection in 1 minute. spirits are real 2016 Screwfix Select. Made from durable, high quality urea with antimicrobial properties. 1. 0mm cables, therefore 2 x 2. talk to ya. 5mm2 spur from socket. Order MK Metal-Clad Plus 13A Unswitched Metal Clad Fused Spur with Neon with White Inserts at Screwfix. 60 days free credit available. Buy any 10+ Save 10% - View Offer. Free returns. Buy online & collect in hundreds of stores in as little as 1 minute! Free returns. 5mm2 to junction box, splitting to: 1. MGW Screwfix Select. 9 amps So do you reckon spur off and install fcu. Online Banking. Pay your way. 5mm T/E through the wall to a 13A switched FCU or Timer module. Raised Slim Profile. Free next day delivery available. 5mm cables via wago connectors. Bazza-spark, Sep 15, 2023. . Screwfix Community Forum. Stylish Brushed Chrome design with screwless metal front plate and concealed fixing screws. Set up eAlerts to protect and track your spending. Home Forums > Screwfix Community Forum > Electricians' Talk > Spur from ring main to socket and fcu. Don't buy Volex rubbish, buy MK or. ”. Need Help. Any questions please ask. Captive Terminal Screws. Reason? the FCU already exists, with it's output disconnected after some changes in the kitchen. terrymac Screwfix Select. All of the lines and rectangles in GREEN are my proposed wiring. Order British General Nexus Metal 13A Switched Fused Spur Brushed Steel at Screwfix. 4. KIAB likes this. Over 40,000 products. Click & Collect. Get the original bathroom fitters to come and move the fcu. Screwfix customers rate this product 4. Buy Schneider Electric FCU Fused Spurs at Screwfix. From the settings menu, click or tap on 'Push Notifications'. Is there any reason that this FCU can't be fixed, by a surface mounted box, to the top of the unit instead of cutting a hole in the back of the unit. The UK’s leading retailer of trade tools and hardware. PostHoc, Feb 24, 2021. Screwfix Community Forum. At the moment FCU is wired to the existing single. You state, “I have taken taken a spur off a socket on the ring cicuit”. Home Forums > Screwfix Community Forum > Electricians' Talk > Outdoor light with separate pir sensor. This utilises a small transformer that is mounted next to a socket by a TV. 51 Inc Vat. 40m/sec Trip Speed. #9. 0mm2 T&E but could be 1. Aug 1, 2009 #3. Order MK Logic Plus 13A. However, this is frowned upon as poor practice. Buy Schneider Electric FCU Fused Spurs at Screwfix. Also, if any circuit needed work doing on it, the electrician could have limited access ( depending on the size of the cupboard)seneca Screwfix Select. to nearby 13amp fused isolation switch. PAGE 1 OF 3. So total 2250 watts. com. Message was edited by: Screwfix Moderator acca, Nov 6, 2011 #26. Deleted member 11267, May 4, 2020. Installing spurs on a new circuit is sloppy. com. Screwless Faceplate. 2. 5 conductor would not be protected by the 32A fuse/mcb. With Flex Outlet. Online Banking is a convenient and secure way to keep up with your finances 24/7. 13A max. The question is would this be ok or should I be using a smaller MCB in the house CU and the. The thermostat was rather special because it set the charging time for the whole floor, depending on the average outside night temperature. An assembly of main and auxiliary switching equipment for operation, regulation, protection or other control of an electrical installation. Apple Pay accepted in store. com. The whole set up from the consumer unit could be a radiel circuit or the spur could be taken from a junction box thats why theres only two cables at each socket. Home Forums > Screwfix Community Forum > Electricians' Talk > Switch FCU (LED not working) Discussion in 'Electricians' Talk' started by sp383, Nov 13, 2018. Its called remote power. To do this drill a small hole just big enough for the flex in the back of the side panel, feed the flex through, fit a plug. diy_master Member. Flexible 13A fuse unit. PayPal accepted online. Discussion in 'Electricians' Talk' started by dabhand, Jul 24, 2007. Actually they are all correctly called fused connection units (FCUs). ? this is the kudox box ip44 rated, again in screwfix website shop. Discussion in 'Electricians' Talk' started by Mole80, May 13, 2023. Just run a twin and earth from the supply side of the existing fcu to the new ones supply side ,and connect both lights to its load side. The current Screwfix Direct Catalogue reflects a range of approximately 15,000 screws, tools, fixings and accessories, which are being offered at more than 140 Screwfix branches throughout the UK. Twin and earth 2. Over 40,000 products. You need to give us more information,specifically what amperage circuit breaker ( or fuse) protects the circuit that the FCU is wired into. 5/5. I've added a socket for the TV and run a length of 2. Install to Depths of 4m. Report your debit card lost or stolen. unphased, Mar 10, 2018 #21. Check stock, order online & collect in as little as 1 minute. The idea is that if the fan jambs it will draw excessive current which will blow the 3 amp fuse before the fire starts! seneca,May 16, 2015. If you want to protect the fan wiring with a 3A FCU or whatever, you could put a cheaper 2 pole FCU on the live/neutral feed to the lighting, saves the expensive of having a 3 pole switch just for the fan. com. com. com. Screwfix Community Forum. The external sockets for the hot tub are at the exact opposite end of the garage from the LED light socket. Buy Screwed FCU Switches & Sockets at Screwfix. Make transfers and loan payments, apply for a loan, get account balances, view and print check copies, print statements, receive email notifications on account balances and so much more!Office Locator. Special guest Allison Russell will open the. Therefore I am proposing: 2. So,you no longer can split ring final to two seperate fcu's & use a bridging link to continue ring final circuit. 2874 for the most current vehicle loan rates or click the button below to complete our quick and easy online application. Order British General 900 Series 13A Switched Fused Spur & Flex Outlet White at Screwfix. Captive Terminal Screws. load. Requires 35mm Back Box. #1. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. Skip to content. Top and bottom tracks included. The idea is that if the fan jambs it will draw excessive current which will blow the 3 amp fuse before the fire starts! seneca, May 16, 2015. Or under the bath, with a panel fitted that requires a tool (screwdriver) to remove panel (say for a shower pump/whirlpool bath)Bazza-spark Screwfix Select. With Flex Outlet. £3. I see,you mean article 48234. All loans subject to credit approval. Hi all looking for some help please… I am in the process of converting my garage in to a room. The UK’s leading retailer of trade tools and hardware. Terminals accept 3 x 2. i dont want to cut another hole in the wall and move it along. 5mm², 2 x 4mm² or 1 x 6mm² cables. Click & Collect. You. Click & Collect. I've heard. Aggregate information from multiple sources to get a complete picture of all your financial relationships. Transfers. So it depends on various things really. bonding either. FREE next day delivery available, free collection in 1 minute. Then establish if the two cables connected to the FCU's supply terminals are part of a ring final ,or a radial circuit. sp383 New Member. The circuit shall be wired with copper conductors having line and neutral. Screwfix customers rate this product 4. It is common practice to install a switched fcu for a cooker hood. Requires 25mm Back Box. com. Terminal Capacity. It should have been installed outside the bathroom. Screwfix customers rate this product 4. Me as well, FCU,& feed running up to a 1G unswitched socket. The reason I asked the original question about the second consumer being fed from a 32 amp RCBO, to a 40 amp 30 mA RCD Consumer Unit, with 2X MCB for lights and sockets. UK call centre ready for your call. Regards isolation they tell me it’s fine because the kitchen sockets are on an independent circuit on the new MCB so isolated there. FREE next day delivery available, free collection in 1. 433. Ind spark, Sep 15, 2023. Without RCD. My question is, without taking it apart again what's the best way to seal the FCU housing to the conduit female accessory, and also the conduit to the female accessory. I have ordered 50m of 10mm swa cable. With RCD. Order British General IP66 13A Weatherproof Outdoor Switched Fused Spur & Flex Outlet with Neon at Screwfix. Without Flex Outlet. View all: FloPlast Underground Pipe Fittings. Apple Pay accepted in store. However, from a practical point of view you would change the present fcu to an unswitched 13A spur, then connect two 3A fcus one serving each of the boiler and the pump. With RCD. Skip to content. Spur off socket to unswitched FCU From unswitched FCU to a switched FCU (needed for functional switching of fly zapper) The load side of SFCU going to the fly zapper and from feed side of SFCU to another SFCU to power outside light. Apple Pay accepted in store. Flex Outlet. PayPal accepted online. Screwfix Community Forum. Buy any 10+ Save 10% - View Offer. A 13A FCU (Screwfix p/n D15777) or 20A DP Switch (Screwfix p/n D13639)? Secondly, the existing consumer unit is one of the old bakelite ones which has probably been here since the house was built in the 50s. Online Banking Benefits. 60 days free credit available. FREE next day delivery available, free collection in 1 minute. Ho hum such is the way of things. com. Requires 35mm Back Box. PayPal accepted online. as per the green lines on the diagram. Need Help. Delivery. After taking a look it appears that the existing outdoor socket is a spur itself, it is fed from an internal single socket (let’s call this the washing machine socket), which is fed by an internal FCU. This means one has to wire a plug and cable. Quite often surge protection extensions have some filtering in them. View all: Masterplug RCD Adaptors. FREE next day delivery available, free collection in 1 minute. Lectrician Screwfix Select. The FCU will have a removable bit of plastic for a flex to go into. Screwfix Select. UK call centre ready for your call 24/7. 5 mm. Home Forums > Screwfix Community Forum > Electricians' Talk > Replacing 13 amp double socket with 2 FCU's. That is fully Regs compliant. Flex Outlet. You made that up. joinerjohn1, Nov 6, 2011 #37. but having a FCU on a spur can cause problems, my dad decided to have a few sockets on a spur, and used a FCU. Sign in / Register. But if you then inserted a 9th socket somewhere in the ring, all of a sudden it would be OK, even though it is blindingly obvious that the mere. On the load side connect a 2. In this case the boiler should be connected using a FCU (spur) and be a fixed appliance. On the load side connect a 2. Thousands of products. And as in te original query - a plug on a cooker hood. Screwfix Community Forum. Need Help. Placing a 2 gang CU with 40A 30mA RCD in the garage with a 20 or 25amp MCB for the 1 double socket. 60 days free credit available. Don't know why there is a switch on the incoming feed, it is not necessary. The UK’s leading retailer of trade tools and hardware. #3. 120-136mm x 100-115mm. My plan was to come off one off my ringmains that feeds my conservatory, go through the wall and fit a ip66 rcd socket and join the swa this. . Home Forums > Screwfix Community Forum > Electricians' Talk > FCU of ring for light. USF FCU offers helpful services like convenience pay, loan skip-a-pay. Power Returns Automatically After Break in Supply. After looking at the switch wiring, it looks like it is a double pole switch with a load and supply. Curiousity about one thing has led me to find something else. the FCU is using the lighting circuit for the power. One for the extra sockets, and the other for the batten light. Need to take account of distance etc etc. Brass. I want to run a spur from the outdoor socket into the shed to power a small wifi camera. Raised Square Profile. We would like to. #5. The UK’s leading retailer of trade tools and hardware. Wiring electric hob diagramWe had to take the whirlpool gas hob/electric oven out and. No. Anyway ,rather than fit a light switch in the kitchen ,which you can do if you wish ,fitting a switched fcu would make the wiring simpler. 5mm swa allowing for voltage drop. Got an air-con system run from a seperate 16A circuit directly from the CU with 20A IP65 rotary isolator next to the outdoor unit. Without RCD. Screwfix Community Forum. com. Wellwisher said: ↑. Added protection against electric shock. £13. I've no idea yet. People do do that with washing machines then put a switch above the worktop. Order British General IP66 13A Weatherproof Outdoor Switched Passive Fused Spur at Screwfix. Some say if the applicance is freestanding and has a moulded 13A plug, it doesn't require an FCU. I was told by a friend that new regs require fcu`s on all appliances such as dishwashers, washing machines etc. Socket spur & FCU. bearing in mind the supply is 6mm cable do you guys have. Flex Outlet. Sign in / Register. Raised Slim. I therefore understood that it was still classed as within zone 2 because it was easily accessible (I have a feeling I may be wrong though from your comments). com. Personally, I wouldn’t put any fcu’s in cupboards ( for the reasons stated in my last post). What you have is basically a socket circuit which is fitted with a fused spur for use with the lighting circuit. The circuit shall be wired with copper conductors having line and neutral conductors with a minimum. #9. 5mm2 2 core and earth. Compression Connection. Buy FCU Switches & Sockets at Screwfix. Stop Payment: Initiate a stop payment request at. $500 minimum deposit. The issue begins because the appliance does not come with a plug or cable fitted. Who said I had no training. Order MK Metalclad Plus 13A Unswitched Metal Clad Fused Spur with White Inserts at Screwfix. #3. g. PaulBlackpool, unphased and FatHands like this. 75% min$500 12-17 month 5. Flex going through a correctly sized hole in the wall looks much neater than a flex outlet plate. Order online at Screwfix. To switch this on or off you switch the switch. 1. Discussion in 'Electricians' Talk' started by seneca2, Nov 27, 2007. You dont, however, state from what source the fcu would be fed? It would also be an inconvenience to you when maintaining the kitchen fan that you would be isolating the f/f at the same time. I currently have an FCU supplying ONE outside PIR security light. -20°C to 40 °C. Terminal Capacity. Don't know why there is a switch on the incoming feed, it is not necessary. Your light now comes off the load side of this with a 3 amp fuse and the two new sockets come. So my new kitchen cupboards are 10mm less depth than the old which has created a problem for my plug in Intergrated oven. Home Forums > Screwfix Community Forum > Electricians' Talk > Double pole switch without FCU Discussion in ' Electricians' Talk ' started by DoItYoung , Feb 9, 2021 . 1, 1957. 30 day money back guarantee. Home Forums > Screwfix Community Forum > Electricians' Talk > Cooker conn unit/FCU. Yes of course there is. touc New Member. HandyAndy - really Mr. Buy online & collect in hundreds of stores in as little as 1 minute! Free returns. Free next day delivery available. There is no rule saying you can’t take two spurs from one point on the ring. I assumed (maybe incorrectly) that what was required above would have been fed off the FCU load as is the cooker hood, so when the FCU switch would be off it would in turn also isolate these new sockets. View all: LAP Fused Spur Modules. The cable coming from the socket will go into the supply side of the spur, take another 2. m. com. Trips at 30mA. The FCU is pointless. com. Non-Latching Operation. 3. 4m x 1. Set Up Account Alerts Today – here’s how it works: 1. Buy FCU Fused Spurs at Screwfix. - - - - Call 24/7 on: 03330 112 112 Call 24/7: 03330 112 112 Shop by. there is absolutely no point in having a CU in the outbuilding. From a Regs viewpoint you can do this as the fan circuit and the f/f circuit would be protected by the fuse in the fcu. Step 2 isolates the entire outside. Apple Pay accepted in store. Could I use this feed to supply further outside lights using a 2 gang switch. Cables safely put in the wall or in trunking. PayPal accepted online. Risteard,May 16, 2015. Flex Outlet. comes with a plug, so it can be disconnected. - - - - Call 24/7 on: 03330 112. . 5 mm is no more than 3 metres long and the cable is in a position where it`s unlikely to get damaged, cos that`s what the brown book says, (butFCU on 1. To repeat myself for claritys sake: -. #4. 99Inc Vat. Suitable for Gravity Drainage & Sewerage. 5mm2 through wall to light. 5mm², 2 x 4mm² or 1 x 6mm². Skip to content. Without RCD. Raised Square. With RCD. For example, with Screwfix Direct Catalogue, you can buy all kinds of high quality building materials, and maintenance and refurbishment items. 30 day money back guarantee. Option 1 looks good but you also need to consider rcd protection and also what's near to those fcu/sockets, like hobs, sinks etc. 5mm2 through wall to socket. I have 3 cables coming through the ceiling to the existing pendant light. Delivered by our approved supplier, Find out more. “From this I intend to spur to an adjacent switched 5 A fused FCU supplying a shower pump. With RCD. diy_master said: ↑. Buy Outdoor Fused Spurs at Screwfix. The idea is that if you take out the fuse, it would stop the dryer from working for sure. Hi all, Just looking for a bit of reassurance here! If an FCU is being used to feed a small load such as an outside light etc. . 3. Raised rounded profile with high gloss finish. Buy online & collect in hundreds of stores in as little as 1 minute! Thousands of customer product reviews. Gland the SWA into the junction box and then feed it outside. However, from a practical point of view you would change the present fcu to an unswitched 13A spur, then connect two 3A fcus one serving each of the boiler and the pump. Everyday products, everyday prices. Have a redundant supply in bathroom cupboard, fed in 2. Screwed Faceplate. 5mm², 2 x 4mm² or 1 x 6mm² cables. com. FREE next day delivery available, free collection in 1 minute. The extractor fan does not have and require a earth wire. 25 gallon Tank with lid. 5mm swa cable and have it coming out of the house and run along the wall into the shed. Screwfix customers rate this product 4. Pay your way. I'd also like to feed some lighting from the new socket with 1. The external sockets for the hot tub are at the exact opposite end of the garage from the LED light socket. Apple Pay accepted in store. joinerjohn1 Screwfix Select. Check for dead. See pic for context. Delivery 7 days a week. 6/5. screwguy, Mar 31, 2005. I also unplugged the washing machine and checked the plug, everything was fine. Pay your way. Discussion in ' Electricians' Talk ' started by PS1964, Jul 11, 2020 . Ash. Personally, I wouldn’t put any fcu’s in cupboards ( for the reasons stated in my last post). Products reviewed by the trade and home improvers. com. FREE next day delivery available, free collection in 1 minute. £ 1. #3. Delivery 7 days a week The UK’s leading retailer of trade tools and hardware. Can’t advise properly unless you can be more specific. 3/5. Terminal Capacity. 20 metre SWA run to a shed. FCU: Switches & Sockets Profile Type: Raised Rounded: Terminal Capacity: Terminals accept 3 x 2. old menace, Jul 23, 2008. The spur both supply and load side have been done in 0. .